Availability : Usually Ships in 2-3 Business Days
- DURA-trol solid bimetal thermostat directly linked to valve porting to control the intake of hot and cold water and compensate for supply temperature and pressure fluctuations. DURA-trol is highly responsive and cannot be damaged by extremes in temperature
- Thermostatic Mixing Valve can be set to the correct temperature for the application
- Locking temperature regulator to prevent accidental movement set for 85°F (29°C)
- Mixing valve will close down on failure of cold water supply
- Mixing valve with special internal cold water bypass capable of 40 GPM (151
l/min) @ 30 PSI (2.1 Bar) upon failure of hot water supply - Maximum operating pressure: 125 PSI (860 KPA)
- Adjustable high temperature limit stop * set for 90°F (32°C)
- Full 1 1⁄4” top or bottom inlets and 1 1⁄2” top outlet
- Integral wall support
- View port in door with, dial thermometer (range 0 to 140F, -10 to 60C)
- Rough bronze finish
- Exposed stainless steel cabinet with hinged door and cylinder lock
- Union angle checkstops on inlets
- Compliance: ANSI Z358.1
ECO-MIX DURA-trol solid bimetal thermostat directly linked to valve porting to control the intake of hot and cold water and compensate for supply temperature and pressure fluctuations. DURA-trol® is highly responsive and cannot be damaged by extremes in temperature. Thermostatic Mixing Valve can be set to the correct temperature for the application. Locking temperature regulator to prevent accidental movement set for 85°F (29°C), Recommended Hot Inlet Temperature 140°F. Mixing valve will close down on failure of cold water supply. Mixing valve with special internal cold water bypass capable of 40 GPM (151 l/min) @ 30 PSI (2.1 Bar) upon failure of hot water supply. Adjustable high temperature limit stop * set for 90°F, (32°C)Integral wall support, Full 1 1/4” bottom or top inlets and 1 1/2” top outlet, Integral wall support, Dial thermometer (range 0 to 140°F, -10 to 60°C), Rough bronze finish, Exposed stainless steel cabinet with hinged door and cylinder lock, Union Angle checkstops on inlets To determine the amount of Hot Water needed to maintain a steady outlet temperature for 15 minutes, click Hot Water Requirements. This guide is not meant to be used as a means to size the hot water heaters but rather to illustrate consumption. This product provides tepid water per the requirements of ANSI Z358.1 This product is certified to meet Low Lead requirements of wetted surface area containing less than 0.25% lead by weight.
WARNING: California Residents
This product and/or packaging can expose you to chemicals including Styrene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.